Premium Honeywell L6006C1018 Wiring Diagram Aquastat Control Wiring Schematic - Wiring Diagrams Schematics

Premium Honeywell L6006C1018 Wiring Diagram Aquastat Control Wiring Schematic - Wiring Diagrams Schematics
Other posts you might like

Premium honeywell l6006c1018 wiring diagram - The way this is typically achieved is to use a strap on aquastat connected to the hot water return line from the boiler coil inside the furnace plenum. You need an aquastat with nc (normally closed) and no (commonly open) terminals like a honeywell l6006c1018. You disconnect the lead that's connected to w at the furnace terminal strip (usually white from the thermostat) then join it to the commonplace terminal at the aquastat. Then connect the aquastat terminal that makes (closes the switch to not unusual) on temp rise to g at the furnace terminal strip and the nc terminal to w at the furnace terminal strip. With it stressed out this manner whilst the water inside the coil is not hot the furnace burner is known as in by way of making r to w and most effective the blower runs with the aid of making r to g when the water inside the coil is hot . Good enough, this control isn't suitable to your software. It's made for an air handler now not a furnace. I can submit a more common solution so that it will work as long as you have g twine linked to the thermostat. Welcome to just solution, my call is ***** ***** i can do my first-rate to help you along with your difficulty. First i’ll need a few more data so i've a more whole picture of you state of affairs. Maximum wood boilers have an aquastat that turns the pump on when the boiler water is up to temp. If you need to govern the pump with a thermostat you operate a pump relay like a taco sr501 to manipulate the pump. The thermostat calls in the relay which turns on the pump or you operate a line voltage thermostat in preference to a low voltage thermostat and a relay. In case you wire an aquastat in collection with the relay pump circuit the pump will most effective run whilst the water is up to temp. Some other method is to neglect the second stat and just have the pump run off an aquastat. This may give you some gravity air flow whilst there's no call for heat from the thermostat however for the reason that wooden boiler is burning all the time this usually has little effect on universal room consolation. There must be a g terminal at the furnace terminal strip where the thermostat is connected. With this technique you simplest need one thermostat. You could use a 2nd thermostat to control the wooden boiler if you like. Right here are the instructions:.

Related post of Premium Honeywell L6006C1018 Wiring Diagram Aquastat Control Wiring Schematic - Wiring Diagrams Schematics